Terminology
The words on a quote, in plain language
A short glossary for the terms that show up on Texas heating and cooling visits. It is a reference, not a sales sheet.
- SEER2
- The current seasonal efficiency rating for cooling equipment. A higher SEER2 uses less electricity to deliver the same cooling, but only if the ducts and the install let the system run as it was tested. It is not a comfort guarantee by itself.
- Tonnage
- Cooling capacity, not weight. One ton is 12,000 BTU per hour. Bigger is not automatically better. An oversized system in a Texas house short-cycles and does a poor job removing humidity.
- Heat pump
- A system that cools and, by reversing, heats. Common as the only heat source in all-electric Greater Austin homes, and used with or without a gas furnace in Dallas–Fort Worth.
- Auxiliary or backup heat
- The heat that carries the house when a heat pump cannot, usually electric strips or a gas furnace. If it runs all winter because the heat pump is locked out, the bill goes up while the house still feels warm.
- Evaporator coil
- The indoor coil that absorbs heat from the house. It sits with the furnace or air handler. A new condenser often needs a matched coil, and a dirty coil can look like a failed compressor.
- Condenser
- The outdoor unit on a split system. It rejects heat to the outside. Cottonwood, pecan pollen, and bent fins all reduce what it can do. It is not the whole system.
- Air handler
- The indoor cabinet with the blower and, usually, the coil. In Texas it often lives in an attic or a closet. The blower serves both heating and cooling.
- Static pressure
- The resistance the blower pushes against. High static pressure means the ducts or the filter are asking too much. Symptoms include a loud system, a collapsing filter, weak rooms, and a coil that freezes.
- Temperature split
- The difference between the air entering the indoor unit and the air leaving it. It is a basic cooling health check. It does not, by itself, prove the charge is correct.
- Short cycling
- The system starts and stops too quickly to do its job. Causes include oversizing, a thermostat in the wrong spot, a dirty filter, or a safety switch tripping. The house often feels clammy.
- Refrigerant
- The fluid that moves heat between the indoor and outdoor coils. It is not a consumable like gasoline. Low charge means a leak or a bad install. Newer equipment uses different refrigerants than systems installed a decade ago.
- Line set
- The pair of refrigerant pipes between the indoor and outdoor units. A replacement quote should say whether the existing line set stays. On ductless systems, the line set path is part of the design.
- Plenum
- The box that connects the air handler to the duct runs. Leaks at the plenum dump conditioned air into the attic or pull attic air into the return. They are a common Dallas and Austin finding.
- Return air
- The air coming back to the system from the house. Undersized or leaky returns cause more ‘weak AC’ complaints than people expect. Closing supplies does not fix a bad return.
- Float switch
- A safety that shuts the system off when the condensate pan is filling up. It is doing its job. The repair is the drain, not a bypassed switch.
- Heat exchanger
- The furnace part that keeps combustion gases out of the house air. If it is cracked, the furnace should be shut down and replaced. It is not a cleaning item.
- Dual fuel
- A heat pump paired with a gas furnace. The heat pump handles milder winter weather and the furnace takes the coldest nights. The thermostat lockout decides when that handoff happens.
- Mini-split
- A ductless heat pump with one or more indoor heads. A good fit for houses without ducts, additions, and single difficult rooms. A poor fit when the existing ducts only need repair.
- Package unit
- Heating and cooling in one box, often on a roof or beside the house. Common on some older Dallas-area homes and on light commercial buildings. Service access is a different job from a split system.
- Commissioning
- The setup work after equipment is installed: airflow, drainage, thermostat configuration, and a real run cycle. Equipment that was set in place and never commissioned is a frequent finding in newer Texas subdivisions.